![]() ![]() This command does NOT clear the fault on the VISTA128BPT itself, therefore the fault must be reset or cleared by the faulted device or panel. The "Clear Zone Fault Notification" driver command clears the variable in the driver for the respective zone if it is not automatically clear by the VISTA128BPT panel. Quick Arming Driver Commands implemented are Away, Home (Stay), Instant, Max, Disarm, Force Away, and Force Home (Stay). One is a master event list which includes status from all partitions the other 8 are individual partition lists for each of the 8 partitions. 9 alarm event lists have been implemented. Up to 8 partitions can be controlled independently. Used for the Entry Notifications and only available if the Automated Exit Timers and Entry Notifications configuration is enabled. For more information on output programming see the "Output Devices Programming" section in the VISTA128BPT programming guide. Example: Enter a 1 in the Partition 1 Entry Trigger slot if Relay 1 on a 4204 Relay Module is set up to active when Partition 1 goes into a "Start of Entry Time" and deactivate when a "Disarming" of Partition 1 occurs. Used for the Exit Timers and only available if the Automated Exit Timers and Entry Notifications configuration is enabled.Īutomated Output Entry Notification Trigger - Enter the output assigned to trigger the entry notification. Also, if the system is armed or disarmed by the control system, it can be separately traced back to the control system, and not necessarily a user.Īutomated Exit Timers and Entry Notifications - Enable if Exit Timers and Entry Notifications are preferred to be triggered from the driver directly.Īutomated Exit Delay - Enter the amount of time in seconds programmed for the exit delay in each partition. This way, the non-control system user codes can be changed without having to reconfigure the driver. It is recommended that a separate user code be set up for the control system in each partition. The polls occur 5 seconds apart.Īlarm Codes - Enter an arming/disarming code for each partition for use with the Quick Arming driver commands. The polling loop increments on each poll and wraps around back to partition 1 after the highest partition has been polled. ![]() This setting is for the keypad display polling loop. Number of Partitions Used - Enter the number of partitions (1-8) in use on the security system. The VISTA 128 BPT TB4 terminal connection should be connected to the RTI system using the following pin configuration. The baud rate can be set to either 1200 or 9600. NOTE - Serial Programming Options for Automations section in the VISTA128BPT Programming Guide/Addendum must be set up appropriately.ġ.01ğixed issue with acquiring zone descriptors from the Honeywell system.ġ.02ğixed issue where perimeter alarm notifications wouldn't trigger the alarm event.ġ.03Ědjusted code for error that may occur when writing information to specified partition event lists.ġ.1Ědjusted partition codes in configuration so codes with leading zeros will work. This driver is for the Honeywell VISTA 128 BPT Security Panel. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |